CO2 exposure, ventilation, thermal comfort and health risks in low-income home kitchens of twelve global cities

Prashant Kumar, Sarkawt Hama, Rana Alaa Abbass, Thiago Nogueira, Veronika S. Brand, Huai-Wen Wu, Francis Olawale Abulude, Adedeji A. Adelodun, Maria de Fatima Andrade, Araya Asfaw, Kosar Hama Aziz, Shi-Jie Cao, Ahmed El-Gendy, Gopika Indu, Anderson Gwanyebit Kehbila, Fryad Mustafa, Adamson S. Muula, Samiha Nahian, Adelaide Cassia Nardocci, William Nelson, Aiwerasia V. Ngowi, Yris Olaya, Khalid Omer, Philip Osano, Abdus Salam, S.M. Shiva Nagendra

Published December 2022
Journal Journal of Building Engineering
Volume 61
Pages 105254
Publisher Elsevier BV
DOI 10.1016/j.jobe.2022.105254

Urban and indoor air quality in Dhaka

Abstract

In-kitchen air pollution is a leading environmental issue, attributable to extensive cooking, poor ventilation and the use of polluting fuels. We carried out a week-long monitoring of CO2, temperature and relative humidity (RH) in five low-income residential kitchens of 12 global cities (Dhaka, Chennai, Nanjing, Medellín, São Paulo, Cairo, Sulaymaniyah, Addis Ababa, Nairobi, Blantyre, Akure and Dar-es-Salaam). During cooking, the average in-kitchen CO2 concentrations were 22.2% higher than the daily indoor average. Also, the highest CO2 was observed for NVd (natural ventilation-door only; 711 ± 302 ppm), followed by NVdw (natural ventilation-door + window; 690 ± 319 ppm) and DVmn (dual ventilation-mechanical + natural; 677 ± 219 ppm). Using LPG and electric appliances during cooking exhibited 32.2% less CO2 than kerosene. Larger kitchens (46–120 m3) evinced 28% and 20% less CO2 than medium (16–45 m3) and small (4–15 m3) ones, respectively. In-kitchen CO2 with >2 occupants during cooking was 7% higher than that with one occupant. 87% of total kitchens exceeded the ASHRAE standard (RH >40%, temperature >23 °C) for thermal comfort. Considering the ventilation type, both the ACH (air change rate per hour) and ventilation rate followed the order: NVdw > NVd > DVmn, while the trend for weekly average CO2 concentration was NVd > DVmn > NVdw. Larger kitchens presented 22% and 28% less ACH, and 82% and 190% higher ventilation rate than medium- and small-volume ones, respectively. Forty-three percent kitchens had ACH <3 h−1 and ventilation rate <4 L/s/person, hence violated the conditions for ideal ventilation. Moreover, 10% of the Hazard Ratio values for 25% kitchens exceeded the CO2 reference value (1000 ppm). Consequently, our findings prompted several recommendations towards improving in-kitchen ventilation and environmental conditions of low-income homes.

Abstract © the authors, published under a CC BY licence.

Cite this

Prashant Kumar, Sarkawt Hama, Rana Alaa Abbass, Thiago Nogueira, Veronika S. Brand, Huai-Wen Wu, Francis Olawale Abulude, Adedeji A. Adelodun, Maria de Fatima Andrade, Araya Asfaw, Kosar Hama Aziz, Shi-Jie Cao, Ahmed El-Gendy, Gopika Indu, Anderson Gwanyebit Kehbila, Fryad Mustafa, Adamson S. Muula, Samiha Nahian, Adelaide Cassia Nardocci, William Nelson, Aiwerasia V. Ngowi, Yris Olaya, Khalid Omer, Philip Osano, Abdus Salam, S.M. Shiva Nagendra (2022). CO2 exposure, ventilation, thermal comfort and health risks in low-income home kitchens of twelve global cities. Journal of Building Engineering, 61, 105254. https://doi.org/10.1016/j.jobe.2022.105254

Related work from the laboratory

Names in bold are laboratory members. The DOI links to the published paper.